go to top scroll for more

CCS Benchmark Refresh - A techno-economic analysis of the performance of a state-of-the art CCGT with and without amine capture at 90% capture rate

This resource links to a data we hold in our archive

Description:

This spreadsheet model was produced as part of the CCS Capture Benchmark Refresh Study, and provides a techno-economic analysis of the performance of a state-of-the art CCGT with and without amine capture at 90% capture rate. The spreadsheet enables 'what if' calculations of costs for the following designs: CCGT with and without capture, at 100% and 40% load; CCGT with and without capture, with 38% and 18% exhaust gas recycle rates, at 100% and 40% load; CCGT with an independent capture plant, generating its own power and steam, at 100% load; CCGT with an independent capture plant, generating its own steam only, at 100% load CCGT with retrofitted capture plant, at 100% load. Outputs include capital costs, operating costs, cost of capture and levelised cost of electricity. The spreadsheet concentrates on power generation, capture and compression, but allows manual input of transport and storage costs to provide overall figures. These cases are covered in Benchmark Refresh reports D2.1 (refresh of CCGT benchmark and EGR) and D7.1 (Independent Capture Plant). It should be noted that the underlying capture plant designs were reviewed as part of the Independent Capture Plant work, so the results given by this spreadsheet for the earlier cases may not precisely match those presented in Report D2.1.

Creator:

Abbot, T., Amec Foster Wheeler

Publisher:

ETI

Citation (APA Style 7th Edition):

Abbot, T., Amec Foster Wheeler (2011). CCS Benchmark Refresh - A techno-economic analysis of the performance of a state-of-the art CCGT with and without amine capture at 90% capture rate [Data set]. ETI. https://doi.org/10.5286/ukerc.edc.000116

Field Dates:

01/01/2009 - 31/12/2018

Data Date Range:

01/01/2011 - 31/12/2031

Data type:

Model

Data format:

application/vnd.ms-excel.sheet.macroEnabled.12

Language:

English

Number of Units:

No unit numbers supplied

Unit Type:

No units supplied

Number of Records:

No records supplied

Parameters:

No parameters supplied

Rights:

Energy Technologies Institute Open Licence for Materials

Rights Overview:

The Energy Technologies Institute is making this document available to use under the Energy Technologies Institute Open Licence for Materials. Please refer to the Energy Technologies Institute website for the terms and conditions of this licence. The Information is licensed "as is" and the Energy Technologies Institute excludes all representations, warranties, obligations and liabilities in relation to the Information to the maximum extent permitted by law. The Energy Technologies Institute is not liable for any errors or omissions in the Information and shall not be liable for any loss, injury or damage of any kind caused by its use. This exclusion of liability includes, but is not limited to, any direct, indirect, special, incidental, consequential, punitive, or exemplary damages in each case such as loss of revenue, data, anticipated profits, and lost business. The Energy Technologies Institute does not guarantee the continued supply of the Information. Notwithstanding any statement to the contrary contained on the face of this document, the Energy Technologies Institute confirms that it has the right to publish this document.

Further information:

N/A

Sector:

Commercial

The Energy Data Centre works in collaboration with the CEDA Archive to provide this information